PCB Piezotronics, Inc. introduces a new triaxial ICP® accelerometer
that installs between rider and vehicle seat, for ride comfort studies and human vibration exposure investigations. Model
356B41 contains a precision, low profile, triaxial ICP® accelerometer, which is mounted to a metal plate and screwed
into a molded rubber pad. The sensor may easily be removed from the pad for calibration and verification
purposes. This mechanical configuration satisfies the requirements of ISO 10326-1. This sensor also supports whole
body vibration studies, in accordance with ISO 2631 and ISO 8041 standards, and supports compliance with EU
physical agents directives.
Model 356B41 has a sensitivity of 100 mV/g (10.2 mV/(m/s²)), frequency range of 0.5 to 1000 Hz (±5%), and
features a 5 ft (1.5m) integral cable and 4-pin terminating connector. The unit operates directly with readout and
analysis equipment, which provide ICP® sensor excitation, or with a separate ICP® sensor signal conditioner. The
unit also operates directly with the Larson Davis Model HVM100 Human Vibration Meter, which supports whole-body
and hand-arm vibration measurements.
Click here to request a quote
|
|